ROPLAST offers top-notch glass facade systems from renowned brands Schüco and AluK, which combine innovative technologies and premium design to meet the demands of modern architecture. These advanced systems allow for the creation of buildings with large glass surfaces that provide natural lighting while ensuring excellent thermal and sound insulation.
FWS 50 CONTINUOUS FACADE
The Schüco FWS 50 facade system is an impressive basic system for facades, offering a high degree of flexibility and attractive design options, including optimized manufacturing and installation processes. Thanks to its wide range of systems, solutions can be implemented for a variety of requirements and applications.
DESCRIPTION
TECHNICAL INFORMATION
Photos
CATALOG
DESCRIPTION
- The transparent system solution integrated into the profile for safety parapet barriers seamlessly and elegantly fits into the exterior appearance of the facade. The required load-bearing capacity of the safety barrier for floor-to-ceiling openings and low parapet heights can be achieved with a consistent visible surface width of the profile and an uninterrupted profile.
- The mullion/transom facade with a visible surface width of 50 mm offers a high degree of design freedom, featuring a wide selection of facade pressed panels and covering caps, as well as the option to combine with Schüco window, door, and sliding system solutions.
- Components optimized for the system ensure easy and reliable integration of electrical components, such as for automated Schüco door or shading systems.
TECHNICAL INFORMATION
- Frame Uf value: (≥) 1.5 W/(m²·K)
- Minimum visible surface width: 50 mm
- Min.-max. system depth: 6…255 mm
- Max. glass/panel thickness: 62 mm
- Max. weight: 1080 kg
- Surface finish: Powder coating, Anodized, Color
- Air permeability: AE
- Maximum sound insulation index: Rwp 48 dB(A)
- Water resistance: RE 1200
- Impact resistance: I5/E5
- Resistance to burglary: Up to RC3
- Suitable for the load of safety parapets: Yes
- Bullet resistance: Up to FB 4
- Minimum basic system depth: 6 mm
- Maximum basic system depth: 255 mm
- Minimum column depth: 50 mm
- Maximum column depth: 250 mm
- Min.-max. column depth: 50…250 mm
- Maximum unit weight: 1080 kg
- Min.-max. visible surface width: 50 mm
- Visible width of the pressed/profile cover: 50 mm
- External visible width: 50 mm
- Internal visible width: 50 mm
- Visible width of the column: 50 mm
- Visible width of the frame: 50 mm
- Visible width of the transom: 50 mm
- Minimum glass/panel thickness: 4 mm
- Min.-max. glass/panel thickness: 4…62 mm
- Maximum glass/infill weight: 1080 kg
- Installation angle: 1-105°
- Polygonal facade angle: 45°
- Minimum vertical slope of the skylight: 2°
- Maximum vertical slope of the skylight: 90°
- Min.-max. vertical slope of the skylight: 2…90°
- Skylight: Yes
- Drainage: Yes
- Drainage level: 3
- DIN EN 62561 lightning protection: Yes
- Earthquake protection: Yes
- Wind load resistance: 2.0/3.0 [kN/m²]
- Connection for shading: Yes
- Integrated sun protection: Yes
- Safety parapet barriers: Integrated, Surface-mounted, Facade-mounted
- Profile-integrated parapet safety barrier: Yes
- Blast resistance: No
- CE mark: Yes
- Compliant with passive houses: Yes
- Passive house class: phA
- Recyclability: Yes
- Standards: DIN EN 1627, EN ISO 10077, DIN EN 13830, General construction approval
- AAMA certificate: Yes
- CWCT certificate: Yes
- Construction approval: Yes
- European technical assessment: Yes
Photos
CATALOG